Skip to main content

GoBe U: Service Errors - What They Mean and How to Fix Them

GoBe U, service error, service 01, service 02, service 03, service 04, service 05, service 06

Written by Anastasia Z.

If your GoBe U smart band displays a Service Error, don’t worry — in most cases, the issue can be resolved with a few simple steps. This article explains what the error means and how to perform a factory reset if needed.

What Is a Service Error?

When a Service Error occurs, GoBe U enters a special mode to signal that something went wrong in the system. In this mode:

  • The band displays a solid red backlight at 30% brightness

  • It emits short red flashes at 100% brightness

  • The number of flashes corresponds to the error code

Error codes and meanings:

  • 01 – Memory error

  • 02 – Functional firmware won’t launch

  • 03 – Internal system error

  • 04 – System bus error

  • 05 / 06 – Communication controller error

Important: Data Loss Warning

To resolve the error, you may need to perform a factory reset. Please note: any unsaved data (e.g., recent steps or calorie intake) may be lost during this process.

Special Case: SERVICE 02

If your device shows SERVICE 02, you might not need a reset. If the band successfully connects to the HEALBE app, the app will prompt a firmware update automatically. Only if this update fails should you proceed with a factory reset.

How to Perform a Factory Reset

Follow these steps:

  1. Turn off the band by pressing and holding the control button for 3 seconds

  2. Press and hold the button again for 7 seconds, then release

  3. Open the HEALBE app and reconnect the band

  4. Set a new PIN code and complete the firmware update

If these steps don’t work or you’re unsure how to proceed, don’t hesitate to contact HEALBE Customer Care. We’re here to help!

Did this answer your question?